7.

 

Operating Temperature 

The most common soldering alloys used in the electronics industry consist of 60% tin and 40% lead. 

The operating temperature of this type of solder is detailed below and can vary from manufacturer to 

manufacturer. However, to meet RoHS requirements, these solders are no longer allowed and are 
replaced by lead-free solders that require a working temperature which is ±30°C (54°F) higher. 

 leaded 

solder 

lead-free 

Melting point 

215°C (419°F) 

220°C (428°F) 

Normal Operation 

270-320°C (518-608°F) 

300-360°C (572-680°F) 

Production Line Operation 

320-380°C (608-716°F) 

360-410°C (680-770°F) 

A good joint is assured if the iron's operating temperature is set within the parameters suitable for the 

type of solder being used. The solder will flow too slowly if the temperature is too low; if the 

temperature is too high, the flux in the solder may burn which will give rise to billowing white smoke. 

In turn, this will result in a dry joint or in permanent damage to the PCB. 

8.

 

Operating instructions 

Refer to the illustrations on page of this manual. 
Verify whether the operating voltage of the unit is identical to that of the electrical supply.  
GENERAL 

 

Make sure the unit's power switch [6] is in the "OFF"-position. 

 

Plug in the soldering iron [5]. Note that the connector has a notch so it only fits in one way. Do not 

force.  

 

Connect the AC power cord to the power connector [7]. Connect the other end to a suitable mains 

outlet. 

 

When applicable, connect an earth wrist strap to the earth jack [9] at the back of the station. 

PARAMETER SETTINGS 

 

Switch on the station [6] 

 

Press the SET-button [2] and hold for at least

 

5 seconds until the display shows “— — —” 

(flashing).Use the 

-button [4] to enter the mode lock password “010” (default) and press the set-

button [2] to go into setup menu. A wrong password will return to normal working mode 

(temperature indication). 

 

In the setup menu, the display will show “F-0”. Press the 

[4]- or 

 [3]-button to select modes. If 

no button is pressed within 15 seconds the device will return to normal operation mode.  

 

 

F-0: exit menu mode 

Press the SET-button [2] when the display shows F-0 to exit the setup menu and return to 

temperature indication.  

 

F-1: password mode 

When password mode is enabled, the user can not change the temperature settings on the 

station unless he or she knows the password. 

Press the set-button [2] once to enter password mode. Press the 

[4]- or 

 [3]-button to 

change display between 000 and 100, with 000 indicating password mode disabled and 100 

indicating password enabled. Press the set-button [2] to return to the setup menu. 

 

F-2: temperature correction mode 

Press the set-button [2] once to enter temperature correction mode. Press the 

[4]- or 

 [3]-

button to enter a correction factor for the temperature, e.g. when the display shows 300°C but 

the actual temperature is only 290°C, add 10°C to the shown correction value. 

Negative values are indicated with a minus in front. Press the set-button [2] to return to the 

setup menu. 

 

F-3: sleep/power off mode 

Enabling sleep/power off mode will lower the irons’ temperature after 20 minutes of inactivity. 

After ±45 minutes of inactivity, the power to the iron is shut off.  

Press the set-button [2] once to enter sleep/power off mode. Press the 

[4]- or 

 [3]-button 

to change display between 000 and 100, with 000 indicating sleep/power off mode disabled and 

100 indicating sleep/power off mode enabled. Press the set-button [2] to return to the setup 

menu. 

When in sleep mode, the temperature is lowered -> 200°C (392°F) and the display is flashing.  

Summary of Contents for VTSSC74

Page 1: ...EL USUA NUNGSANLE OLDERING CERAMIC ND SOLDEE EGELING UDAGE C GLABLE OLDADURA AJUSTABLE T SCHNELLE GELUNG K DLEIDING ARIO ITUNG STATION HEATER ERSTATION KERAMISC CHAUFFEME L MENT CON CALEN ELEMENT ER A...

Page 2: ...oit des droits d auteur pour cette notice Tous droits mondiaux r serv s Toute reproduction traduction copie ou diffusion int grale ou partielle du contenu de cette notice par quelque proc d ou sur tou...

Page 3: ...o your distribu al rules e disposal aut se read the man transit don t ins uct and the lat power cord 0 8mm and s ildren and unau roducts or in ex ering tip as this ween uses alwa e r when the devi cor...

Page 4: ...witch 2 SET button 7 power connector 3 down button 8 fuse 4 up button 9 earth jack a barrel d heater element b nut e heater holder c bit f handle A temperature indication B heating indication 6 Descri...

Page 5: ...til the display shows flashing Use the button 4 to enter the mode lock password 010 default and press the set button 2 to go into setup menu A wrong password will return to normal working mode tempera...

Page 6: ...life span if used properly Always tin the tip before returning it to the holder prior to turning off the station or to storing it for long periods of time Wipe the tip on a wet sponge or use our tip...

Page 7: ...s only Ve from incorre ut prior notice UIKERSHA ese Unie effende dit pro de verpakking g ade kan toebren e huishoudelijke U moet dit toes ecteer de plaatse dan de plaatse andleiding grond t installeer...

Page 8: ...tsgara el binnenshuis Plaats geen ob extreme hitte Z en en vermijd br tel kennen voor wijzigingen aa et onder de gar het gemaakt is door het negere eid afwijzen voo uente technolog egeling via pasw ar...

Page 9: ...ten loodvrije soldeer smelt aan een temperatuur die gemiddeld 30 C 54 F hoger ligt dan dat van loodsoldeer loodsoldeer loodvrij soldeer Smeltpunt 215 C 419 F 220 C 428 F Normale werking 270 320 C 518...

Page 10: ...ren mag u geen temperaturen gebruiken die de 410 C 770 F overstijgen U kunt het toestel wel kortstondig gebruiken bij hogere temperaturen maar dan moet u heel voorzichtig zijn OPGELET Om brandwonden t...

Page 11: ...ngse oeft u enkel de koelen Het toes nt niet werd ver r weg wanneer draai de schroe n WEES ECHTE ment worden be schoon met ee el nooit in een v Gebruik geen s r uw verdeler of s rmingselement ginele a...

Page 12: ...r s usage c ble d alimenta e renouveler le m es de soudur ative la prote r un circuit sous les condensateu de qualit Ve uement l int mais placer d ob re Prot ger co pas bloqu es s et le traiter av ent...

Page 13: ...p rature de soudage entre 100 et 520 C 212 968 F sans n cessiter un remplacement de la panne ou de l l ment d chauffement La temp rature est maintenue dans une marge de 3 C 5 4 F de la temp rature de...

Page 14: ...e de la panne Enfoncez le bouton SET 2 pour acc der au menu S lectionnez 000 mot de passe d sactiv ou 100 mot de passe activ avec le bouton 4 ou 3 Renfoncez le bouton SET 2 pour revenir au menu princi...

Page 15: ...emp ratures excessives qui d passent donc 400 C ou 750 F N appuyez pas trop fort sur la panne pendant le soudage pour viter tout endommagement vitez l usage de limes et de mati res abrasives lors du n...

Page 16: ...alaje in as si las hubier vuelva este apa s en relaci n co toridades loca C74 Lea atentam a o en el transp roducto y la ve w velleman eu ura con cable de 0 8mm y sopor dad alcance de perso productos i...

Page 17: ...a o goteo a polvo No exp ficios de ventila e usar excesiva o del aparato an ficaciones no au torizadas no es caciones descrita e las instruccion esponsable de n a tecnolog a de o trase a orrar energ a...

Page 18: ...necesita una temperatura m s elevada de unos 30 C 54 F esta o con plomo esta o sin plomo Punta de fusi n 215 C 419 F 220 C 428 F Funcionamiento normal 270 320 C 518 608 F 300 360 C 572 680 F Uso en la...

Page 19: ...per odos cortos EN ESTE CASO SEA EXTREMADAMENTE CUIDADOSO OJO Evite quemaduras no toque las partes met licas del soldador durante el uso o la refrigeraci n Ponga el interruptor de alimentaci n en la...

Page 20: ...la ornille s lo el di iento adecuado tivada sin reemp el polvo del sop n una pinza par puede hacer fun n un pa o h me e que no pueda esentante en ca ntador para el so cesorios origin uso indebido cio...

Page 21: ...ehen S ht oder durch sc kraft das Kabel e ein Entsorge wenn der elektro es ab und entla it tsgarantie a t nur im Innen Ger t keiner Fl vor Staub Sch ftungsschlitze rungen Vermei eb nachdem Si aus Sich...

Page 22: ...OS Ger te usw vor Stromst en und Spannungsspitzen die bei weniger effizienten mechanisch geschalteten Stationen zu Besch digung f hren Die Heizelemente sind galvanisch vom Netz getrennt durch einen Is...

Page 23: ...e Temperatur 300 C reelle Temperatur der Spitze 290 C f gen Sie 10 C hinzu Ein negativer Celsiuswert wird mit einem Minuszeichen angezeigt Dr cken Sie SET 2 um zum allgemeinen Konfigurationsmen zur ck...

Page 24: ...anbringen Lassen Sie das ger t bis 250 C 482 F erhitzen und stellen Sie nach ungef hr 3 Minuten die gew nschte Temperatur ein Das Ger t ist betriebsfertig wenn die gew nschte Temperatur erreicht wird...

Page 25: ...van de aankoopsom bij ontdekking van een gebrek tot n jaar na aankoop en levering of een vervangend product tegen 50 van de kostprijs of terugbetaling van 50 bij ontdekking na n jaar tot 2 jaar Valt...

Page 26: ...an si el aparato ya no est cubierto por la garant a Cualquier reparaci n se efectuar por el lugar de compra Devuelva el aparato con la factura de compra original y transp rtelo en un embalaje s lido p...

Reviews: