AC70T Crane Purpose VFD Manual
25
F2.36
UP/DW terminal
control mode
0: Off electricity storage
1: Off electricity not storage
2: Valid in running, clear zero at stop
0
〇
0x224
F2.37
ACC/DEC speed of
UP/DW terminal
controlling frequency
0.01-50.00Hz/s
0.50Hz/s
●
0x225
F2.38 Reserved
0x226
F2.39
Timer time unit
0: Second
1: Minute
2: Hour
0
●
0x227
F2.40 Timer
setting
value
0-65000
0
●
0x228
F2.41
Counter max value
0-65000
1000
●
0x229
F2.42
Counter setting value
0-65000
500
●
0x22A
F2.43 Reserved
0x22B
F2.44
Output terminal polarity
selection
0: Positive 1: Negative
LED “0” digit: Terminal Y
LED “00” digit: Relay output terminal
1
LED “000” digit: Relay output terminal
2
0000
●
0x22C
F2.45 Output
terminal
1
Refer to 4.2 Function selection table
1
●
0x22D
F2.46 Relay
output
1
32
●
0x22E
F2.47 Relay
output
2
32
●
0x22F
F2.48
Y1 output delay time
0.000-6.000s
0.010s
●
0x230
F2.49
Relay 1 output delay
0.000-6.000s
0.010s
●
0x231
F2.50
Relay 2 output delay
0.000-6.000s
0.010s
●
0x232
F2.51
Output frequency level 1
(FDT1)
0.00-Max frequency
2.00Hz
●
0x233
F2.52
FDT1 lag
0.00-Max frequency
1.00Hz
●
0x234
F2.53
Output frequency level 2
(FDT2)
0.00-Max frequency
2.00Hz
●
0x235
F2.54
FDT2 lag
0.00-Max frequency
1.00Hz
●
0x236
F2.55
Given frequency arriving
checkout range
0.00-50.00Hz
2.00Hz
●
0x237
F2.56
Y1 output invalid delay
time
0.000-6.000s
0.010s
●
0x238
F2.57
Relay 1 output invalid
delay time
0.000-6.000s
0.010s
●
0x239
F2.58
Relay 2 output invalid
delay time
0.000-6.000s
0.010s
●
0x23A
4.5
Analog Terminal Parameter Group
NO.
Function description
Range of settings and definition
Factory
setting
Feature
Address