AC70T Crane Purpose VFD Manual
27
F3.29
Valid state setting when
analog used as terminal
0: low level 1: high level
LED 0 digit: VS
LED 00 digit: AI
LED 000 digit: AS
LED 0000 digit: reserved
0000
●
0x31D
F3.30
Analog input curve
selection
LED “0” digit: VS
0: Beeline (default)
1: curve 1
2: curve 2
LED “00” digit: AI (Select voltage or
current input by wire jumper)
LED “000” digit: AS
LED “0000”digit: reserved
0000
●
0x31E
F3.31
Reserved
0x31F
F3.32
Curve 1 lower limit
0.00
~
10.00V
0.00V
●
0x320
F3.33
Curve 1 lower limit
corresponding setting
0.00
~
100.00%
0.0%
●
0x321
F3.34
Curve 1 inflection point 1
input voltage
0.00
~
10.00V
3.00V
●
0x322
F3.35
Curve 1 inflection point1
corresponding setting
0.00
~
100.00%
30.00%
●
0x323
F3.36
Curve 1 inflection point 2
input voltage
0.00
~
10.00V
6.00V
●
0x324
F3.37
Curve 1 inflection point2
corresponding setting
0.00
~
100.00%
60.00%
●
0x325
F3.38
Curve 1 upper limit
0.00
~
10.00V
10.0V
●
0x326
F3.39
Curve 1 upper limit
corresponding setting
0.00
~
100.00%
100.00%
●
0x327
F3.40
Curve 2 lower limit
0.00
~
10.00V
0.00V
●
0x328
F3.41
Curve 2 lower limit
corresponding setting
0.00
~
100.00%
0.00%
●
0x329
F3.42
Curve 2 inflection point 1
input voltage
0.00
~
10.00V
3.00V
●
0x32A
F3.43
Curve 2 inflection point1
corresponding setting
0.00
~
100.00%
30.00%
●
0x32B
F3.44
Curve 2 inflection point 2
input voltage
0.00
~
10.00V
6.00V
●
0x32C
F3.45
Curve 2 inflection point2
corresponding setting
0.00
~
100.00%
60.00%
●
0x32D
F3.46
Curve 2 upper limit
0.00
~
10.00V
10.00V
●
0x32E
F3.47
Curve 2 upper limit
corresponding setting
0.00
~
100.00%
100.00%
●
0x32F
F3.48-F3.52
Reserved
0x330