AC70T Crane Purpose VFD Manual
17
FF.27
Running current
detection time
0.000
~
1.000s
0.400s
〇
0xF1B
FF.28
Light load upscaling
function selection
0: Invalid 1: Judging by current 2:
Judging by weight
0
〇
0xF1C
FF.29
Load measurement
time
0.000
~
5.000s
1.000s
〇
0xF1D
FF.30
Upward upswing
judgment threshold
0.0
~
80.0%
50.0%
〇
0xF1E
FF.31
Up frequency up
frequency limit
0.00
~
Max frequency
65.00Hz
●
0xF1F
FF.32
Downward upselling
threshold
0.0
~
80.0%
50.0%
〇
0xF20
FF.33
Downward frequency
up frequency
0.00
~
Max frequency
65.00Hz
●
0xF21
FF.34-FF.35 Reserved
FF.36
Rotary flexible control
option
LED ‘0’ digit: rotary flexible control
0: off 1: open
LED ‘00’ digit: flexible control
acceleration and deceleration time
0: off 1: open
LED ‘000’ digit: Reserved
0000
●
0xF24
FF.37
Flexible control starting
deviation frequency
0.00
~
20.00Hz 2.50Hz
●
0xF25
FF.38
Flexible control direction
changes deviation
frequency
0.00
~
20.00Hz 2.50Hz
●
0xF26
FF.39
Flexible control
acceleration time 1
0.00
~
650.00s 20.00s
●
0xF27
FF.40
Flexible control
deceleration time 2
0.00
~
650.00s 20.00s
●
0xF28
FF.41
Acceleration/deceleratio
n time 1 switches to the
frequency of
acceleration/deceleratio
n time 2
0.00
~
Max frequency
0.00Hz
●
0xF29
FF.42
Acceleration/deceleratio
n time 2 switches to the
frequency of
acceleration/deceleratio
n time 3
0.00
~
Max frequency
0.00Hz
●
0xF2A