AC70T Crane Purpose VFD Manual
15
Chapter 4 Function Parameter Table
This chapter just provides function parameter table. Specifications refer to AC200 technical manual or inquiry the
company.
“●”:
Parameter can be changed in the running state.
“〇”:
Parameter can’t be changed in the running state.
“×”:
Parameter can be read only.
“–”:
Factory setting parameter, only factory can set.
“※”:
Parameter is related to the model.
Special parameters group
4.1 Lifting special parameter group
NO.
Function description
Range of settings and definition
Factory
default
Feature
Address
FF.00
Application type
selection
0: General
1: hoisting mechanism (closed loop)
2: Translation mechanism
3: Rotating mechanism
4: Construction lift
5: Lifting mechanism (open loop)
5
〇
0xF00
FF.01
Brake mode selection
LED ‘0’ digit: brake release
0: frequency opens
1: frequency and current associated
with opening
LED ‘00’ digit: starting direction
selection
0: The torque is the same as the
running direction
1: The torque is always in the forward
direction
LED ‘000’ digit: stop direction
selection
0: The torque is the same as the
running direction
1: The torque is always in the forward
direction
LED ‘0000’ digit: brake control
frequency jump
0: invalid
1: valid
1001
〇
0xF01