AC70T Crane Purpose VFD Manual
29
4.6 System Parameter Group
NO.
Function description
Range of settings and definition
Factory
setting
Feature
Address
F4.00
Parameter and key lock
selections
0: Not locked
1: Function parameter locked
2: Function parameter and key
locked (except for
RUN/STOP/JOG)
3: All function parameter and key
locked
0
●
0x400
F4.01
User password
0
~
9999
0
●
0x401
F4.02-F4.03
Reserved
0x402
F4.04
LCD keyboard language
selection
0: Chinese
1: English
0
●
0x404
F4.05
Parameter copy
0: No function
1: Send inverter parameters to
keyboard and save
2: Send keyboard parameters to
inverter
Remaining value: no operation
0
〇
0x405
F4.06
Keyboard special
function selection
LED 0 digit: D\E monitor on
0: Off
1: On
LED 00 digit: no keyboard
potentiometer lock sampling
value
0: Off
1: On
LED 000 digit: reserved
LED 0000 digit: reserved
0000
〇
0x406
F4.07
REV/JOG selection
0: REV 1: JOG
0
〇
0x407
F4.08
STOP key setting
0: Non-keyboard control mode is
invalid
1: Non-keyboard control mode stop
according to stop mode
2: Non-keyboard control mode stop
according to free mode
1
〇
0x408
F4.09
UP/DOWN key selection
LED “0” digit: keyboard
UN/DOWN key modify selection
0: Invalid
1: Modify frequency setting by key
board numbers F0.08
0011
〇
0x409