21
5 Connecting to power supply
VEGAFLEX 82 • 4 … 20 mA/HART - two-wire
44222-EN-170220
5. Insert the cable into the sensor through the cable entry
Fig. 9: Connection steps 5 and 6 - Single chamber housing
Fig. 10: Connection steps 5 and 6 - Double chamber housing
6. Insert the wire ends into the terminals according to the wiring plan
Information:
Solid cores as well as flexible cores with wire end sleeves are insert-
ed directly into the terminal openings. In case of flexible cores without
end sleeves, press the terminal from above with a small screwdriver,
the terminal opening is then free. When the screwdriver is released,
the terminal closes again.
You can find further information on the max. wire cross-section under
"
Technical data - Electromechanical data
"
7. Check the hold of the wires in the terminals by lightly pulling on
them