background image

16 

 

Autoscale[X]: 

Select 

Autoscale[X]

 to automatically scale collected data by scaling the 

abscissa (X) width to full screen.

 

Autoscale[Y]: 

Select 

Autoscale[Y]

 to automatically scale collected data by scaling the 

ordinate (Y) height to full screen.

 

Zoom Out: 

Select 

Zoom Out

 to Zoom back to the original X and Y axis scaling set in the 

Cary Setup tab. This will undo all zooming.

 

Add Label : 

Select 

Add Label

 to display the Add Label dialog box to enable you to place 

a text label on your graph. 

 

Add Picture : 

Select 

Add Picture

 to display the Add Picture dialog box to insert a 

picture, bitmap or chemical structure into your graph. 

 

Edit Annotation: 

Select 

Edit Annotation

 to alter the content or look of an annotation 

(such as a label or a picture) in the Graphics area.

 

Delete Annotation: 

Select 

Delete Annotation

 to remove an annotation (such as a label 

or a picture) from the Graphics area.

 

 

 

Single/Multi Graph : 

Select 

Single/Multi Graph

 to toggle between displaying one or all 

graphs. 

 

Auto Arrange Graphs: 

Select 

Auto Arrange Graphs

 to view and arrange all graphs 

simultaneously.

 

Copy Graph: 

Select this to copy the Graphics area onto the Windows Clipboard.

 

Paste to Graph: 

Select this to paste the contents of the Windows Clipboard into the 

Graphics area. Text is pasted as a label; graphics are pasted as pictures.

 

Add Graph: 

Click 

Add Graph

 to add a new graph box to the Graphics area.

 

Remove Graph: 

Click 

Remove Graph

 to delete the selected graph box from the 

Graphics area.

 

Clear All Traces: 

Select 

Clear All Traces

 to delete all traces from the graph/s.

 

User Data Form: 

Select this to display the 

User Data Form

.

 

Maths: 

Select this to enable the 

Maths window

. This option is only available when right-

clicking in a graph box.

 

History List: 

This displays a list of the current graphs. 

2)

 

Trace Preferences  

A single graph box can display many traces. This window enables you to select the 

trace(s) to display (make visible) in the selected graph box or color space. Trace 
Preferences is accessible from the Graph menu, by right-clicking on a trace or by 
clicking on the toolbar. 

The Trace Preferences menu is also available by right-clicking anywhere in the 

trace listing. 

Summary of Contents for Cary 5000

Page 1: ...n on computer 2 Check lens and mirror are correct for your measurement a Install Small Sample Kit mirror M3 SSK or regular M3 mirror if needed b If using SSK install correct lens L2 3 Make sure cover...

Page 2: ...e Turn on the instrument 0 I switch on the lower left side of the front of the instrument In the Scan program watch the lower left corner to see the status of the instrument When the traffic light is...

Page 3: ...mounts in front of the sample see Figure 4 There are three lenses that can be used again for the three positons marked as T C or R Each time the sample configuration is changed the optics need to be...

Page 4: ...T C and R for the three positions of the integrating sphere Also the large mirror M3 is switched out for a one with a different curvature this mirror is always kept in the T position regardless of the...

Page 5: ...on located in the upper left hand corner defines the scan parameters The following useful tabs can be found under Setup Cary tab Here you can set the units of the x and y axes nm cm 1 etc and A T R et...

Page 6: ...be applied to a sample where the abscissa range of the sample exceeds that of the baseline If you change your abscissa range to one outside that of the baseline the Cary will display an error message...

Page 7: ...x at the end of a collect where you can enter the Batch file name for your data Note In the Scan application Prompt at Start and Prompt at End save information as a DSW file unless there are multi or...

Page 8: ...multiple graphs in the Graphics area You can double click on the Graphics area to toggle the display through graph and report to graph only The graph functions can also be accessed by clicking one of...

Page 9: ...ich Text Format file How to Export Collected Data If you want to export data from a Cary WinUV application into a third party application then save your data as an ASCII CSV file To do this 1 Click Fi...

Page 10: ...eck box is not checked 8 In the File name field type in the file name for your new batch file 9 Click Save to create the new batch file The current method will be stored with the batch files All the d...

Page 11: ...SBW will change automatically to maintain the required signal level If you are collecting data in double beam mode across the UV Vis and NIR regions with Fixed SBW set as the Measurement Mode then you...

Page 12: ...nes for another Scan run you simply open the file using either the File Open Data command or click the Baseline button in the Baseline tab of the Setup dialog box Note If you decide that you do not wa...

Page 13: ...gle bounce relative SRA accessories should not use this correction Select a Baseline Zero correction instead This correction is performed with the raw transmission data and due to the double bounce on...

Page 14: ...owever sometimes you may notice that the text has turned to gray and is in italics This indicates that the Cary is currently idling outside the abscissa range of the baseline file but that the current...

Page 15: ...ferences and Graph Preferences options 1 Graph menu options Print XY point Select this to print the cursor s current X and Y coordinates in the report area This option is only available when right cli...

Page 16: ...to Arrange Graphs Select Auto Arrange Graphs to view and arrange all graphs simultaneously Copy Graph Select this to copy the Graphics area onto the Windows Clipboard Paste to Graph Select this to pas...

Page 17: ...in traces You can resize the Name of Trace and File name fields by selecting and dragging the splitter bar between the fields File Name This field displays the file name and path of the trace If the n...

Page 18: ...il the font is changed again Trace Style This field allows you to define the way that your trace will appear on screen Points Each individual data point collected by the Cary is shown on the graph Poi...

Page 19: ...e right side of each graph box A single click on a sample name or example line within the legend will make it the focused or red scan Information about the trace will be displayed below the X axis Dou...

Reviews: