Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s), one a time until the end of the list is
reached. To review the error messages again, it will be necessary to access them using the Status
function.
Refer to next page for a list of possible causes and remedies associated with the error messages.
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until
Fixt
(Fixture) appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows to access
STAT
. Press [Enter]. (Display will now scroll through
any error messages or display
OK
if no errors.)
Table A-1: Error Messages
Display
Message...
OK
No Errors Found
B2M1 / RLen / NoSn
Aux Board 2, Motor 1 / Rotating Lens / Sensor Not Found
B2M1 / RLen / SAct
Aux Board 2, Motor 1 / Rotating Lens / Sensor Always Active
BRD1 / NO / COMM
Aux Board 1 Communication Failure
BRD2 / NO / COMM
Aux Board 2 Communication Failure
HEAD / OVER / TEMP
Head Over Temperature
LAMP / STRK / FAIL
Lamp Strike Failure
PAN / ENCR / FAIL
Pan Encoder Failure
PAN / NO / SENS
Pan Sensor Not Found
PAN / SENS / ACTV
Pan Sensor Always Active
SCR / LOW / VOLT
SCR Dimmer / Low Voltage
SCR / NO / BULB
SCR Dimmer / No Bulb
SCR / OVER / CRNT
SCR Dimmer / Over Current
SCR / WRNG / BULB
SCR Dimmer / Wrong Bulb
SRCH/FOR/BRD1
Attempting to communicate with Board 1
SRCH/FOR/BRD2
Attempting to communicate with Board 2
TILT / ENCR / FAIL
Tilt Encoder Failure