02.9661.0001 K
Align Lamp for Flat Field
After a new lamp is installed, it will be necessary to align the lamp to optimize the beam. Screws
located at the luminaire’s backcap will allow adjustment.
WARNING:
Backcap and adjustment screws will be HOT during lamp operation. Wear gloves and/
or use tools to prevent burns.
To align lamp for flat field:
Step 1. Using internal menus select
Lamp
test to set beam. See
“Menu System” chapter on page 43
for more information. (If using console, set intensity to 100% and adjust diffusion to
produce a tight beam.)
Step 2. Position beam on a white wall at a distance of 10' to 20'.
Step 3. Using three adjustment screws, adjust hot spot to center of beam.
Figure 2-7: Lamp Adjustment Controls
Lamp Adjustment
Screws