I
NSTALLATION
: I
NSTALLATION
P
ROCEDURES
2
02.9661.0001 K
09-Apr-03
17
Installing in Truss:
Step 1. Using two people, lift luminaire into mounting position.
Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g.
wing bolt) is properly tightened and that luminaire is fully supported.
Step 3. Attach safety cable (as required) as follows:
a. Connect one end of cable to luminaire handle.
b. Loop at least once around truss/pipe and attach other end of cable to other handle.
Step 4. Connect power and data cables according to procedure given in
Figure 2-5: Hanging Configuration and Dimensions
23.75”
(60.33cm)
31.375”
(79.7cm)
19.25”
(48.9cm)
24”
(61cm)
Head Swing
Diameter
***
***
Safety Cable
:
Recommended for hanging installations.
May be required by local codes.
Handles are
approved for
safety cable
anchor points
33.125”
(84.2cm)
*
From lens to top of bracket