O
PERATION
: U
PDATING
S
OFTWARE
3
02.9661.0001 K
09-Apr-03
41
Step 7. Download will proceed. (Download will take 1-2 seconds.) One of the following will occur:
The receiving luminaire’s green Rx LED will blink rapidly and its menu will display
number of blocks received (this number will vary depending on software version being
downloaded). This indicates that data is being sent from luminaire to luminaire. However, if
display does not show blocks as they are received, this indicates that the version being
downloaded matches the one already installed or that the luminaire type does not match.
If the receiving luminaire’s green Rx LED does not blink rapidly and its menu does not
display blocks, this indicates that no data is being received. (Check cable connections,
Loopback Connector, etc. and ensure ALL cabling is the 5-conductor type.)
Note:
Without any data connected, the normal standby cycle of the Rx LED is 2 sec on, 2 sec off.
Note:
The number of blocks displayed will be less in a luminaire-to-luminaire download than in a PC-
to-luminaire download for the same software version.
Step 8. Once download is complete, luminaire will automatically recalibrate. Once recalibration is
complete, luminaire is ready for operation with its new software version.
Verify software version at luminaire:
Step 1. At Menu Display, press [Menu].
Step 2. Press [Up] / [Down] arrows until
Fixt
appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until
Ver
appears. Press [Enter].
The first half of the version date will be displayed as MM/DD/YY (month/day/year): For
example,
07/21/02
= July 21, 2002
Press [Up] / [Down] arrows to display second half of version date.
The second half of the version date will be displayed as XXX (time in 6 minute intervals):
For example,
36.0
= 36 minutes
Correct
Trouble