Rainger Linear 45
OPERATION
Closed Delivery
Start Up
1. Inspect the wheel tracks to insure no vehicles or
other equipment will be contacted upon start-up
or operation.
2. If the machine is equipped with below ground
guidance, turn the oscillator ON.
3. Connect or start power source.
• If equipped with an Electric Cord, refer to
Electric Cord Handling and Operation begin-
ning on page 43, then return to this instruc-
tion and continue with step 9.
• If equipped with an Engine/Generator, con-
tinue with step 4.
4. Check the engine fuel, coolant, and oil levels.
5. If equipped with a centrifugal pump, check the
centrifugal pump oil reservoir level.
6. At the engine control panel, move the Remote
Shutdown toggle switch to the Bypassed posi-
tion. See Figure 45-1.
7. Push the Reset button on the water pressure
gauge.
8. Push and hold the red Safety button in while
turning the Engine Start switch to START. When
the engine starts, turn the Engine Start switch to
the ON position and the safety button will hold
itself in.
9. Turn the control panel disconnect to the ON posi-
tion.
10. If equipped with an Engine/Generator, check the
voltmeter reading and verify that the generator is
producing the correct Nominal Supply Voltage for
this machine. See Figure 45-2.
11. Determine how the machine will be run.
• If running the machine wet, with water, refer to
Side Inlet Hose and Cord Positioning begin-
ning on page 49 or Center Inlet Hose and
Cord Positioning beginning on page 53,
then return to this instruction and continue
with step 12.
• If running the machine dry, without water con-
tinue with step 14 or if applicable, refer to Side
Inlet Hose and Cord Positioning beginning on
page 49 or Center Inlet Hose and Cord Po-
sitioning beginning on page 53, then return
to this instruction and continue with step 14.
3
1
2
4
Figure 45-1 1. Safety Button
2. Toggle Switch
3. Engine Start Switch
4. Water Pressure Gauge Reset
Nominal
Supply Voltage
Maximum
Allowed Voltage
Minimum
Allowed Voltage
480 VAC @ 60Hz
505 VAC
440 VAC
415 VAC @ 50Hz
420 VAC
375 VAC
400 VAC @ 50Hz
420 VAC
365 VAC
380 VAC @ 50Hz
420 VAC
355 VAC
230 VAC @ 60Hz
253 VAC
220 VAC
120 VAC @ 60Hz
132 VAC
105 VAC
110 VAC @ 50Hz
121 VAC
95 VAC
Figure 45-2
!
CAUTION
• DO NOT OPERATE THE MACHINE IF THE
VOLT METER READS BELOW THE MINIMUM
ALLOWED VOLTAGE OR ABOVE THE MAXI-
MUM ALLOWED VOLTAGE. SEE FIGURE 45-2.
• OPERATING THE MACHINE OUTSIDE THESE
LIMITS COULD CAUSE DAMAGE TO THE
DRIVE MOTORS AND OTHER ELECTRICAL
COMPONENTS.
• CORRECT THE LOW VOLTAGE PROBLEM
BEFORE RESUMING OPERATION.
Summary of Contents for Rainger Linear
Page 2: ...2 Rainger Linear This page was left blank intentionally...
Page 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Page 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Page 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...