OPERATION
Side Inlet
Hose and Cord Layout
When using the side inlet, position the hose as shown. See Figure 49-1.
•
The hose layout distance from the water pipeline varies depending on hose diameter.
•
The cart path must be maintained in a smooth, hard condition, to allow the poly hose to slide freely over
the surface.
•
The side inlet hose drag is designed to reverse at the ends of the field without disconnecting the poly hose
from the cart.
•
The side inlet swivel elbow should be adjusted outward to an angle of at least 10° in order for the machine
to reverse consistently.
•
The side inlet configuration can greatly reduce hose handling labor compared to the center inlet configura-
tion, but should not be expected to auto-reverse completely unattended.
•
Due to the tight bending radius in the poly hose, and the stresses of auto-reversing, it is recommended to
use heavier (SDR 15.5 or SDR 13.5) wall poly hose for side inlet hose drags.
•
Hose bumpers may be installed to push the poly hose out of the way of the cart tires.
•
At the ends of the field, where reversing direction takes place, maintain a smooth, hard area on the inlet side
of the cart, so that the poly hose can slide freely over the surface when reversing.
.
Riser
Guidance (Furrow or Cable)
Poly
14’
[4.27m]
(4”)
20’
[6.10m]
(6”)
16’
[4.88m]
(4-3/4”)
with Bumpers
Riser
Guidance (Furrow or Cable)
14’
[4.27m]
(4”)
20’
[6.10m]
(6”)
32’
[9.75m]
(8”)
16’
[4.88m]
(4-3/4”)
without Bumpers
centerline of Cart path
EOF to 1st riser =
poly length - 50 ft.
Intermediate riser spacing =
(2x poly length) - 80 ft.
Intermediate
Riser
Figure
Figure 49-1 Side Inlet Hose Layout
1. Side Inlet
2. Hose
3. Water Pipeline
4. First Riser
5. Intermediate Riser
Smooth, Hard Area At Each End
Of Field For Hose To Slide Over
When Reversing Direction.
14 ft
(4.27 m)
4 in. Hose
4
7
2
1
8
6
6
5
20 ft
(6.10 m)
6 in. Hose
16 ft
(4.88 m)
4-3/4 in. Hose
GUIDANCE
FURROW OR CABLE
Intermediate riser spacing =
(2 x poly hose length - 30 ft (9.14 m))
End of field to first riser =
(same as poly hose length)
3
6. Hose Bumper (optional)
7. Electric Cord (optional)
8. Power Pedestal
9. Alternate Power Pedestal Location and Electric Cord Position
Bury The Electric Cord In
This Area To Allow Cart And
Hose To Pass Over It.
9
Summary of Contents for Rainger Linear
Page 2: ...2 Rainger Linear This page was left blank intentionally...
Page 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Page 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Page 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...