44 Rainger Linear
OPERATION
Closed Delivery
Electric Cord Operation
3. Turn the power pedestal disconnect switch to the
OFF position. See Figure 44-1.
!
DANGER
• THE DISCONNECT SWITCH MUST BE IN
THE “OFF” POSITION WHEN INSERTING OR
REMOVING THE PLUG FROM THE RECEP-
TACLE.
4. Remove plug cap from electric cord plug, and in-
sert the electric cord plug into the power pedestal
receptacle. See Figure 44-1.
!
WARNING
• ALWAYS ATTACH THE PLUG CAP TO THE
PLUG WHEN MOVING THE ELECTRIC CORD
FROM ONE POWER PEDESTAL TO ANOTHER
OR WHEN STORING THE ELECTRIC CORD.
5. Place the cord anchor cable
through the mechanical cable
anchor ring on the power ped-
estal.
For proper operation of the
cord anchor cable disconnect,
there must be slack in the elec-
tric cord between the cord grip
and plug when the cord anchor
cable is pulled taut. See Figure
44-2.
!
WARNING
• DO NOT ATTACH ELECTRIC
CORD PLUG TO POWER
PEDESTAL RECEPTACLE
WITH PLUG CAP COLLAR.
6. Turn the power pedestal dis-
connect switch to the ON posi-
tion to energize the cart discon-
nect panel.
4
7
6
7
3
6
1
1
2
2
3
4
5
5
8
8
10
9
11
12
Figure 44-2
1. Power Pedestal
2. Plug Cap
3. Electric Cord Plug
4. Power Pedestal Receptacle
5. Cord Anchor Cable
6. Cable Anchor Ring
7. Electric Cord
8. Cord Grip
9. Disconnect Switch- OFF
10. Disconnect Switch - ON
11. Cable is Slack
12. Cable is Taut
1
2
3
4
5
Figure 44-1
1. Disconnect Switch
2. Power Pedestal
3. Plug Cap Collar
4. Plug
5. Receptacle
Summary of Contents for Rainger Linear
Page 2: ...2 Rainger Linear This page was left blank intentionally...
Page 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Page 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Page 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...