Rainger Linear 71
OPERATION
Swing Around
Pivot Procedure (continued)
7. Remove the torque and clevis pins securing the pivot swivel lever in the closed position. See Figure 71-1.
8. Pull the pivot swivel lever to open the pivot swivel latch. Some force may be required to open the latch. See
Figure 71-1.
9. With the pivot swivel lever in the open position, store the torque and clevis pins in lever mount. See Figure
71-1.
10. Repeat steps 7-9 for the other lever.
NOTE
• If a latch DOES NOT open, use the override
button to jog the span in one direction then
the other direction to release the latch.
• The Override button only functions in the
pivot mode when at least one of the latch
proximity sensors are NOT activated.
11. Select the direction of movement for the span to
pivot. See Figure 71-2.
• Press
for reverse.
OR
• Press
for forward.
12. Press
to start the machine in the pivot
mode. See Figure 71-2.
2
1
4
3
2
5
1
6
7
Figure 71-1 1. Torque Pin
2. Clevis Pin
3. Pivot Swivel Lever (CLOSED POSITION)
4. Pivot Swivel Latch (CLOSED POSITION)
5. Lever Mount
6. Pivot Swivel Lever (OPEN POSITION)
7. Pivot Swivel Latch (OPEN POSITION)
!
WARNING
• TO REDUCE THE POSSIBILITY OF STRUC-
TURAL DAMAGE, BOTH OF THE PIVOT
SWIVEL LEVERS AND LATCHES MUST BE IN
THE OPEN POSITION BEFORE ATTEMPTING
TO PIVOT THE SPAN.
MANUAL
PIVOT A
477 VOLTS
48.0 HR
0. . DEG
0. .PSI
100 %
0.25 IN
RUNNING
FORWARD
WATER OFF
SIS. 500
1
2
3
Figure 71-2 1. Reverse Key
2. Forward Key
3. Start Key
Summary of Contents for Rainger Linear
Page 2: ...2 Rainger Linear This page was left blank intentionally...
Page 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Page 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Page 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...