![Valley Rainger Linear Owner'S Manual Download Page 98](http://html1.mh-extra.com/html/valley/rainger-linear/rainger-linear_owners-manual_3240098098.webp)
98 Rainger Linear
TROUBLESHOOTING
Tower Ahead Shut Down
In a tower ahead shut down, the tower which is out of line and the farthest ahead fails to shut off and breaks
the safety circuit.
!
WARNING
• TO REDUCE THE POSSIBILITY OF STRUCTURAL DAMAGE, NEVER REVERSE THE DIRECTION OF
TRAVEL AFTER A TOWER AHEAD SHUT DOWN. AFTER MACHINE IS REPAIRED, ALWAYS OPER-
ATE IN THE SAME DIRECTION OF TRAVEL AS BEFORE THE SHUT DOWN. WHEN THE MACHINE
COMES BACK INTO ALIGNMENT THE DIRECTION CAN BE CHANGED.
Tower ahead shut downs typically occur because of a component failure in the tower box. Some causes of
tower ahead shut downs are shown below. Call your Valley Dealer to diagnose and repair a tower ahead shut
down. Refer to the operation pages of this section or the control panel Owners Manual for other TROUBLE-
SHOOTING information.
DIRECTION
OF TRAVEL
TOWER AHEAD SHUT DOWN
TOWER CONTACTOR FAILURE
TOWER CONTACTOR SUPPRESSOR
FAILURE
RUN MICROSWITCH FAILURE
CALL VALLEY DEALER
TOWER BOX SWITCH PIVOT ARM
BOUND UP
CALL VALLEY DEALER
CALL VALLEY DEALER
CALL VALLEY DEALER
CALL VALLEY DEALER