MUS0330202
03/10/2014
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
76
Warning: When you wish to check the tank adhesive level, you can
do so while the equipment is loading, without any problem, as the
micro (sensor) installed on the cover allows the equipment to detect
when the cover is opened and stops the vacuum feeding. Once the
cover is closed, it will begin loading again automatically.
Note: Never operate the applicator if the tank is empty. If the quantity
of hot-melt material is very small, the adhesive may degrade, leading
to the carbonisation of the HOT-MELT material, and the formation of
deposits inside the unit. This may lead to unnecessary downtimes
later on.
Emptying the Tank:
Before emptying the tank, put on a face shield, gloves and long-sleeve
shirt to prevent possible burns caused by hot adhesive splashing.
1.
Warm the equipment to the working temperature.
2.
Reduce the air pressure to zero.
Vibrator
Input for the
pellets
Suction
tubes set
Air tube