MUS0330202
03/10/2014
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
82
6.2. MAINTENANCE RECOMMENDATIONS:
The following table shows the frequency with which maintenance
operations should be performed
:
Frequency
Maintenance
Weekly
(40 hours)
Clean the outer surface of the equipment. Use a liquid
cleaner, following the instructions for the adhesive being
used.
Inspect all the electric, pneumatic and hydraulic
connections. Replace or repair when necessary
Bleed the drain valve.
6 Months
(2000 hours)
Change the air regulator filter.
Clean the tank filter.
Operation frequency depends on the type of adhesive used and the
environmental conditions where the equipment is placed.
6.3. MAINTENANCE PROCESSES:
6.3.1. Cleaning the equipment
Vacuum the dust or glue remnants, or remove them with a soft cloth,
especially from the manifold and bleed valves.
Clean the control panel periodically with a soft cloth. Do not use
solvents, which could damage the control panel.
Use a soft cloth to remove dust and glue remnants from the cylinder,
valve and exhaust mufflers.
If you use a cleaning agent, make sure that it is compatible with the
adhesive being employed.
When in doubt, contact the adhesive manufacturer.
6.3.2. Bleeding the pressure regulator air filter:
Bleed the air-regulation unit by pushing the lower button on the filter.
Change the regulator filter as necessary, depending on the
contaminants that accumulate in the pneumatic system.