4.3.19. AUTOMATIC PUMP MODE
When the Automatic Pump Mode is on, the pump will automatically
start when the system reaches temperature and the System Ready
LED illuminates.
If the Ready Delay Time is enabled and set for a preset time (15
minutes), the pump will not start and the unit will not be ready until 15
minutes AFTER the control has gotten to temperature.
The factory default setting is OFF.
This parameter can be accessed in Password Level 2 or higher.
4.3.20. POT FILL MODE
In this mode of operation, melted glue is pumped into an external pot
when the external lever control falls below a set level. The external
level control is wired to the external level input on the CPU, J6.
In this mode, the pump turns on ONLY when it receives a signal from
the external level input, and the unit is ready. Normal pump operation
is ignored in this mode. The automatic pump mode should be ‘On.’
Pattern control and valves are typically not used in this operating
mode.
On-delay time is set by the operator to
delay pump activation ‘x’
seconds after the external level input calls for glue.
After the delay time expires, the pump will turn on and run until the
external pot level triggers the level sensor that the pot is full, and the
pump then turns off.
This parameter can be accessed in Password Level 2 or higher