3. Referring to the chart above, locate the appropriate voltage
selector plug and power connector label corresponding to
the incoming electrical service.
4. Adhere the appropriate power connector label to the power
connector on the 12 zone board (see illustration).
Warning: The label must be correctly oriented on the power
connector.
5. Remove the power connector from the 12 zone board and
connect the power cable leads to the power connector
terminals as shown in the chart above.
6. Install the appropriate voltage selector plug into the
connector marked J15 on the 12 zone board (see
illustration).
7. Plug the power connector into the 12 zone board (see
illustration).
8. Verify that all connectors are fully seated and the power
connector terminal screws are secure.
9. Close the electrical enclosure door.
240V 3Ø
029XX435
POWER INPUT
240VAC, 1 PHASE
240VAC, 3 PHASE
400/380, 3 PHASE
40A MAX.
12 Zone Power Board
3.6.3 Input/Output Connections
The Input/Output connection interface is on the J-23 & J-24 terminals,
on the bottom of the CPU Board. The CPU Board is located directly
behind the Keypad.
There are four opto isolated inputs rated for +24VDC @ 15mA each,
that can be programmed by the user for a variety of options. See the
chart below.