50 • vacon
FAULT TRACKING
112
0x70
PresetRPM
Get_Attribute_Single,
Set_Attribute_Single
N/A
0
30000
C7
Sets safe state speed reference (RPM) if
the Safe State Behavior attribute specifies
"Preset Speed/Direction".
Alarm: Review the application for safe
operation before specifying a value for
this attribute.
Inverter will require external stop.
113
0x71
PresetTq
Get_Attribute_Single,
Set_Attribute_Single
N/A
0
10000
C7
Sets safe state torque reference (0,00%) if
the Safe State Behavior attribute specifies
"Preset Speed/Direction".
Alarm: Review the application for safe
operation before specifying a value for
this attribute.
Inverter will require external stop.
120
0x78
Polled Input
Assembly Type
Get_Attribute_Single
Set_Attribute_Single
71
70
73
75
107
C7
Input assembly used by the polled
connection
121
0x79
Polled Output
Assembly Type
Get_Attribute_Single
Set_Attribute_Single
21
20
23
25
101
C7
Output assembly used by the polled
connection
176
0xB0
User Label
Get_Attribute_Single,
Set_Attribute_Single
N/A
N/A
N/A
DA
User Supplied name for the Instance.
Maximum of 8 characters
Summary of Contents for NX OPTC7
Page 1: ...vacon nx ac drives optc7 devicenet option board user manual ...
Page 51: ......