46 • vacon
FAULT TRACKING
7 SpeedActual[RPM]
Get_Attribute_Single
N/A, C3
Actual drive speed (best approximation)
0x07
0
Units: RPM
30000
8 SpeedRef[RPM]
Get_Attribute_Single,
1 C3
Speed reference
0x08
Set_Attribute_Single
1
Units: RPM
30000
9 CurrentActual[100mA
]
Get_Attribute_Single
N/A, C3
Actual motor phase current
0x09
0
Units: 100mA
32767
10 CurrentLimit[100mA] Get_Attribute_Single
N/A, C3
Motor phase current limit
0x0A
0
Units: 100mA
32767
11 TorqueActual[Nm]
Get_Attribute_Single
N/A, C3
Actual torque
0x0B
0
Units: Nm
32767
12 TorqueRef[Nm]
Get_Attribute_Single,
0 C3
Torque reference
0x0C
Set_Attribute_Single
0
Units: Nm
10000
15 PowerActual[W]
Get_Attribute_Single
N/A, C3
Actual output power
0x0F
0
Units: Watts
32767
16 InputVoltage[V]
Get_Attribute_Single
N/A C3
Input Voltage
0x10
180
Units: Volts
690
17 OutputVoltage[V]
Get_Attribute_Single
N/A C3
Output Voltage
0x11
0
Units: Volts
690
20 LowSpdLimit[RPM]
Get_Attribute_Single
0 C7
Minimum speed limit
0x14
0
Units: RPM
30000
21 HighSpdLimit[RPM] Get_Attribute_Single
1800 C7
Maximum speed limit
0x15
0
Units: RPM
30000
29 RefFromNet
Get_Attribute_Single
N/A C1
Status of torque/speed reference
0x1D
0
0 = Local torque/speed reference
1
1 = DeviceNet torque/speed reference
176
0xB0
User Label
Get_Attribute_Single,
Set_Attribute_Single
N/A
N/A
N/A
DA
User Supplied name for the Instance.
Maximum of 8 characters
Summary of Contents for NX OPTC7