4
5
6
7
4
5
6
7
4
5
6
7
-
+
-
+
Actual value
External 24V
Supply
(0)4..20mA
Drive 1: Standard I/O Board
Drive 2: Standard I/O Board
Drive 3: Standard I/O Board
Terminal
Signal
Terminal
Signal
Signal
A12+
A12-
24V
out
GND
Analogue input 2+
Analogue input 2-
24V auxiliary voltage
I/O ground
A12+
A12-
24V
out
GND
Analogue input 2+
Analogue input 2-
24V auxiliary voltage
I/O ground
A12+
A12-
24V
out
GND
Analogue input 2+
Analogue input 2-
24V auxiliary voltage
I/O ground
Fig. 97: Wiring of the same sensor for all drives (supplied from an external 24V)
If a sensor is supplied from the I/O board of the drive and the diodes are connected between
terminals 12 and 17, the digital inputs must be isolated from the ground. Set the isolation
DIP switch to Float.
The digital inputs are active when they are connected to GND, which is the default condition.
PARAMETER DESCRIPTIONS
VACON · 331
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/