40
APPLICATION TABLE - INDIRECT HOT WATER TANK SIZING
HEATING ONLY BOILERS 100, 125, 165
Notes:
176 °F Boiler Supply Water Temperature, AHRI Conditions -50 °F Inlet
Water @ 240 GPH Flow Rate.
Model
Max. First
Hour Rating
Continuous
Rating
Boiler Output
Needed For
Maximum
Performance
Boiler
Water Flow
Through
Coil
Pressure
Drop
Through Coil
Gal/Hr. @
Gal/Hr @
(BTU/Hr)
Gal/Min
(Ft. Water)
140 F 115 F 140 F 115 F
H20I30
176
233
149
206
112,000
14.0
5.7
H2OI40
193
254
157
218
118,000
14.0
5.9
H2OI40L
186
251
150
215
116,000
14.0
5.6
H2OI50
196
254
151
231
125,000
14.0
6.2
H20I60
231
298
177
244
132,000
14.0
6.4
H20I60L
211
272
157
218
118,000
14.0
5.9
H2OI80
241
306
169
234
127,000
14.0
6.2
H2OI115
291
363
188
260
141,000
14.0
6.7
High Output Units 60HO, 80HO, and 115HO
H2OI60HO
353
468
299
414
221,000
14.0
10.5
H2OI80HO
366
479
294
407
220,000
14.0
10.3
H2OI80HOC
386
507
314
435
236,000
21.0
15.8
H2OI15HO
413
532
310
429
232,000
14.0
10.8
H2OI115HOC
423
545
320
442
240,000
21.0
16.7
Extra High Output Units 85XHO and 115XHO
H2OI85XHOC
649
868
571
790
428,000
28.0
13.0
H2OI115XHOC 674
893
571
790
428,000
28.0
13.0
PN 240012875 REV. C [10/01/2021]
Summary of Contents for MACF-115
Page 2: ...MACF 150 ...
Page 4: ...MAHF 125 ...
Page 74: ...70 A 1 MODEL 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Page 75: ...71 A 2 MODEL 125 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Page 76: ...72 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013371 REV B 10 01 2021 ...
Page 77: ...73 APPENDIX A WIRING DIAGRAMS A 4 MODEL 115 Combi 240013371 REV B 10 01 2021 ...
Page 78: ...74 A 5 MODEL 150 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Page 79: ...75 A 6 MODEL 205 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Page 80: ...76 NOTES 240013371 REV B 10 01 2021 ...
Page 81: ...77 NOTES 240013371 REV B 10 01 2021 ...
Page 82: ...78 NOTES 240013371 REV B 10 01 2021 ...
Page 117: ...33 MODEL 100 Heat Only 100 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Page 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Page 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Page 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Comb PN 240012875 REV C 10 01 2021 ...
Page 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Page 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Page 127: ...43 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES PN 240012875 REV C 10 01 2021 ...
Page 132: ...48 3 FAULT SOLUTION SECTIONS PN 240012875 REV C 10 01 2021 ...