Troubleshooting
5-8
The Utah-400
Control Panel Troubleshooting
If your control panel does not control any of the matrix, check that power is applied to the
panel.
•
Panels communicate to the controller by a special network known as U-Net. Panels are
connected together daisy chain style to the controller. Removing a panel physically from
the network will break the chain and disconnect panels downstream from the controller.
•
U-Net uses unshielded twisted pair cable. It requires two twisted pairs terminated in an RJ
45 connector. The maximum length of any segment is 1000 feet and must be terminated at
the last control panel in each segment. Refer to the Appendix C "U-Net Cabling" for details.
•
The panel may be communicating to the controller correctly, but the required signal level
matrix may not be responding. Check the Dipswitch setting on the rear panel of the non-
functional router level.
Confirm that the control panel address is a unique number. Each panel address
is set by a rear panel Dipswitch and must be a unique address. This control
panel address is read when the control panel is powered up.