The Utah-400 Digital Audio Breakout Panel
C-2
The Debug Port
The Breakout panels are generic; they may be used for either sources or destinations.
Each panel is silk screened from 0 on the left, to 71 on the right. Each labeled block on the rear
of the panel corresponds to the labeled block on the front of the panel.
Installation of the AES Breakout Panel
To install the Breakout Panel:
1.
Install the BOP at the desired location on the rack frame. (Within three feet of the Utah-
400 Digital Audio Backplane.)
2.
Install the D/D 26 pin cables from the Utah-400 input or output 00 - 07 to the BOP back-
plane input or output 00 - 07. Continue in the same manner for each input or output for
the remaining eight blocks on the breakout panel.
3.
Unpack the Field Wiring Kit and connect the required sources or destinations to each of
the tension clamp connectors. Refer to Figure D-2, on the following page for wiring
each tension clamp connector.
FIGURE C-1.
Wire Prep
1.
Insert the small screwdriver into the rectangular holes to release the wire clamp.
2.
Insert the wire into the round hold above or below the rectangular slot.
3.
While holding the wire in the hole, pull out the screwdriver (inserted in Step 1).
4.
Tug on the inserted wire to verify that it is properly clamped.
5.
Repeat for the entire connector.
Summary of Contents for Utah-400 iP
Page 1: ...The Utah 400 Digital Routing Switcher 64x64 Systems System Setup and Operations ...
Page 26: ...Introduction 1 14 The Utah 400 ...
Page 52: ...Hardware Installation 2 26 The Utah 400 ...
Page 122: ...Specifications A 8 The Utah 400 ...
Page 136: ...The Debug Port B 14 The Debug Port ...
Page 142: ...The Utah 400 Digital Audio Breakout Panel C 6 The Debug Port ...
Page 146: ...TOC 4 The Utah 400 ...