64x64 Router
2-5
Mounting Equipment in Rack Frames
b. Install two rack screws into the empty rack frame below the height determined in
step a, above. These screws will be used to support the weight of the chassis when
it is moved into the rack frame. See Figure 2-3, Section A.
c. With two persons, pick the chassis up from the shipping carton at the left and right
side frames.
d. Move the chassis to the 19" rack frame and carefully slide it into the rack frame,
hooking the flange of the chassis above the rack screws installed in step b., above.
See Figure 2-3, Section B.
Note: An alternative method is to support the Utah-400 Chassis with a shelf
or similar support and align the mounting holes accordingly.
e. With the chassis resting on the lower rack screws, carefully lift the left side frame,
align the lowest chassis frame mounting hole with a rack frame threaded hole and
start rack screw. Repeat for the right hand side frame.
f. Once the lower chassis rack screws are in place, snug both sides up, but do not
tighten.
g. Align remaining six mounting holes, install remaining six rack screws through
mounting holes and then snug them down.
h. Finally, tighten all eight rack screws installed in the chassis mounting holes.
4.
Replace all front covers when the installation is complete.
FIGURE 2-3.
Sliding the Utah-400 Chassis into Rack Frame
Utah-40
0
L
eft
S
ide
Frame
#10 Rack Screw
A
Slide Utah-400 Chassis
into 19" Rack Frame
19" Rack Frame
Summary of Contents for Utah-400 iP
Page 1: ...The Utah 400 Digital Routing Switcher 64x64 Systems System Setup and Operations ...
Page 26: ...Introduction 1 14 The Utah 400 ...
Page 52: ...Hardware Installation 2 26 The Utah 400 ...
Page 122: ...Specifications A 8 The Utah 400 ...
Page 136: ...The Debug Port B 14 The Debug Port ...
Page 142: ...The Utah 400 Digital Audio Breakout Panel C 6 The Debug Port ...
Page 146: ...TOC 4 The Utah 400 ...