Control System Interconnection
3-6
The Utah-400
•
Battery Error. Will illuminate when the battery is low.
•
Sync LED -- Will illuminate when a composite signal is in place -- allowing vertical interval
switching.
•
Ethernet link -- Illuminates when the ethernet port is in use.
SC-400 Jumper Settings
•
J2 Switch -- Used to clear the RAM
•
JP1 -- Serial Port 2
•
JP2 -- Serial Port 1
SC-400 Dipswitch Setting
User Switch 0
When set, the system will initiate a software load, though the Linux application itself will not
start. This is typically used for factory troubleshooting.
User Switch 1
User switch 1 determines which of the two memory banks is in use. A change to either mem-
ory partition (0 or 1) will not affect the other. The actual switch position determines which mem-
ory partition is in use.
User Switch 5
Used to start the Linux operating system, but not the actual application.
User Switches 2 - 4
Undefined at this time.
Bypass Switch
Also used for factory troubleshooting. The default configuration is all switches positioned
toward the silkscreened numbers, or to the
right
as the board is viewed from the front.