Page 24
5.
AES/EBU input connector (RJ45) – parallel connections to the DB25F to the right.
6.
Ethernet connector (RJ45) – Network communications with GUI, web browsers,
automation, etc.
7.
AES/EBU input connector (DB25F) – Eight channels, DMA8 pin out.
8.
Automation DB25F Connector – Receives automation pulses from other system
components. Ten Control input lines with ground and 5V power provided to support a
standard pulse to ground system. The 5V output can power a JSDV-‐80 remote volume
control that pulses control lines 9 and 10.
9.
Crossover bypass output levels for high and low bands.
10.
COAX -‐ RCA type connector (PCM) with optional DTS® and Dolby Digital®
decoding.
11.
Crossover balanced stage high band (L, C, R) and LFE 2 outputs.
12.
TOSLINK Port – Optical Fiber input (PCM) with optional DTS® and Dolby Digital® decoding.
13.
Crossover bypass frequency and mode selection switches.
14.
Hearing Impaired/Visually Impaired-‐Narrative outputs.
15.
Eight channel analog outputs. Low band on screen channels, full range on surround
channels.
16.
Six channel analog input on DB25F – Balanced line inputs.
17.
Non Sync (N/S) connectors – L and R analog inputs, RCA type connectors.
18.
Public Address and Real Time Analyzer microphone phantom power supply selector, 12V
balanced, 9V unbalanced, and off.
19.
Public Address and Real Time Analyzer microphone – XLR and ¼” stereo jack with
configurable phantom power.
7.6
BLU LINK OUTPUT REAR PANEL CONNECTIONS (JSD-‐60LN OR JSD-‐60DN)
1.
Power entry Module – Accepts IEC-‐type line cord from 100-‐240VAC power source. Also
contains a 500mA Slo-‐Blow 5x20mm fuse.
2.
Bypass Power Supply – 12VDC at 1.25A.
3.
RS-‐232 on a DE9F connector for communications with GUI or automation.
4.
SD Card – Stores a backup copy of unit configuration. Can also be used to transfer settings
to another unit or read by the GUI to download to a connected unit.
5.
AES/EBU input connector (Top RJ45) – parallel connections to the DB25F to the right.
Ethernet connector (Bottom RJ45) – Network communications with GUI, web browsers,
automation, etc.
6.
AES/EBU input connector (DB25F) – Eight channels, DMA8 pin out.
7.
Automation DB25F Connector – Receives automation pulses from other system
components. Ten Control input lines with ground and 5V power provided to support a