Page 20
•
Eight Channel Audio Output -‐ DB25M. Eight balanced outputs for full range or low band (if
crossover option installed).
•
Crossover Audio Output -‐ DB25M (crossover option only). Balanced outputs for left, center,
and right high band plus LFE2.
•
AES/EBU Audio Output – Two RJ45 connectors (AES/EBU output option only). Six AES/EBU
pairs: left low, left high, center low, center high, right low, right high, Ls, Rs, Lrs, Rrs, LFE,
LFE2. When biamp mode not selected, low band outputs become full range.
•
BLU link Audio Output – Two RJ45 connectors (BLU link option only). Drives 96kHz BLU link
loop as master providing left low, left high, center low, center high, right low, right high, Ls,
Rs, Lrs, Rrs, LFE, LFE2. When biamp mode not selected, low band outputs become full range.
Processing
•
96 kHz processing.
•
One-‐third octave equalization on all channels except LFE, HI, and VI-‐N.
•
Parametric equalizers on LFE.
•
Synchronization delays for all inputs.
•
Surround delays for all surround channels.
•
Optional Internal crossovers. Crossovers support biamp with 3 screen channels plus
individual parametric equalization and two LFE outputs. Crossover includes a speaker library
and allows for user defined speaker systems.
Bypass Mode
In an emergency situation, the JSD-‐60 can be switched off, automatically enabling the bypass
circuitry. Front panel buttons, LEDs, display, and fader will still function, allowing the operation
of the unit in various analog and digital formats. Final output is a monophonic signal fed to the
left and right channels. Bypass circuitry only drives analog outputs, not AES/EBU or BLU link
outputs. Note: The 12 VDC bypass power supply must be connected for this functionality.
Graphical User Interface
The JSD-‐60 Graphical User Interface (GUI) operates under Windows XP, Windows 7, and
Windows 8. It communicates with one or more JSD-‐60 systems simultaneously over USB,
Ethernet, or RS232. The GUI is used for system configuration including auditorium equalization
(both manual and automatic equalization).
Dynamic Range:
Typically 105dB.
Power Requirements:
100-‐240VAC, 50/60Hz, 30 watts maximum (18 watts typical).
Dimensions:
Standard 1U rack-‐mount chassis.
Agency Approvals: