DS1061-015B
5
It is possible to configure the following system times:
Alarm
: it is the alarm output activation time (sirens or other) in case of:
Intrusion alarm, with armed system (intrusion outputs only).
Tamper alarm, also with disarmed system (intrusion outputs only).
Rescue alarm, also with disarmed system (rescue outputs only).
Low battery/failure alarm, also with disarmed system (Low battery/failure alarm outputs only).
.seconds.time.must.be.used.exclusively.for.test.purposes.
Entry (Pre-alarm)
: it is the delay time starting when the delayed input (input 1) detects an intrusion attempt. During this time, alarm signals, if
present,.are.ignored,.allowing.people.to.enter.in.protected.premises.to.disarm,.by.keypad.or.key,.the.alarm.system..Entry.time.is.interrupted.
by disarming totally or partially the system. During entry time, the keypad buzzer sounds intermittently. When entry time is elapsed and the
partition.including.the.input.1.has.not.been.deactivated,.the.control.panel.generates.an.intrusion.alarm.
Exit
: it is the delay time starting when the system is partially or totally armed; when the time is elapsed, the system is activated. During this
time,.alarm.signals,.if.present,.are.ignored,.allowing.people.to.leave.the.premises.that.will.be.protected.by.the.alarm.system..Exit.time.can.be.
interrupted.by.disarming.totally.or.partially.the.system..During.exit.time,.the.keypad.buzzer.sounds.intermittently..
230V mains fail alarm
:.it.is.the.time.that.must.elapse.without.30V.power.supply.before.the.control.panel.sends.the.related.alarm.vocal.
message, SMS and with digital protocol (depending on message kind, are required PSTN and GSM telephone lines, connections and a
subscription with an alarm reception centre). Time calculation is reset every time 230V power supply is available again for 5 consecutive
minutes..1.minute.time.setting.must.be.used.exclusively.for.test.purposes..
Technological alarm
: it is the alarm outputs activation time (sirens and other), configured as technological, in case of Technological alarm;
alarm.is.generated.also.with.disarmed.system.
5.4.7 KEYS PROGRAMMING MENU
The control panel
automatically shows the first
free memory location
(01 - 02 – 03 …) for
acquisition of Master or
User key.
For deleting, keep
OK
button
pressed for 2 seconds: the
LCD display blinks for 3 times
and all the keys are deleted.
If the control panel has not
stored Master codes, the
display shows blinking
and it is not possible to exit by
pressing ESC button until a
new Master key is acquired.
ESC
OK
ESC
OK
OK
OK
OK
ESC
OK
ESC
OK
...
...
Key
acquisition
Keys
deleting
Master
User
Main programming menu
To acquire a new electronic or transponder key, insert or bring it near the reader. In case of successful acquisition, the control panel LCD display
blinks to confirm and a double acoustic signal is emitted (beep beep); on readers all leds turn on for some seconds.
If is inserted a key already acquired, all readers leds blink at the same time for some seconds.
The control panel can acquire up to 10 keys; the shown number is the key identifier.
•
•
•
•
•
•
•
•
•