unbalancing. caused. by. a. short. circuit. activates. a. tamper. alarm. even. if. the. system. is. disarmed.. Possible. types. of. intrusion. input. are. the.
following:
Immediate (Lines 2-6)
: the intrusion signal is sent as soon as the input is opened or unbalanced; it is the only type available for input from
.to.6.
Delayed (Line 1)
:.the.input.opening.or.unbalancing.starts.the.Entry.Time,.during.which.all.the.alarms.signalled.by.the.other.inputs.are.
ignored..If,.when.the.Entry.Time.is.elapsed,.the.alarm.system.has.not.been.disarmed,.the.control.panel.activates.the.programmed.alarm.
signalling. It is the only type available for input 1).
Rolling shutter
:.the.intrusion.alarm.is.generated.when.is.detected.by.the.rolling.shutter.detector.a.given.number.of.pulses..Two.levels.of.
sensitivity.are.possible:.
High
:.the.alarm.is.generated.when.the.rolling.shutter.has.made.a.travel.of.about.15-0cm.
Low
:.the.alarm.is.generated.when.the.rolling.shutter.has.made.a.travel.of.about.40cm..
Technological
: the input opening generates a technological alarm, even if the system is disarmed. The input is always active (H24). This is the
configuration for the input to which are connected smoke, gas, flood or similar detectors, if present.
Rescue
: it is an input always active (24H); its opening generates a rescue alarm.
Not used
: it is the configuration to be used for inputs to which no detectors are connected (open input).
.
An input can have only one of the above described configurations.
The tamper input (tamper) can not be programmed nor excluded.
5.4.4 OUTPUTS PROGRAMMING MENU
When pressing the
OK
button
to confirm the selection, the
LCD display blinks for 3 times
and appears the dot down on
the right corner.
ESC
OK
ESC
OK
Main programming menu
OK
OK
OK
OK
OK
Output 1
Output 2
Intrusion alarm
Pre-alarm
Technological alarm
Rescue alarm
Low battery/failure alarm
Only the two auxiliary relay outputs 1 and 2 are programmable. The output configuration determines which alarms will cause the relay contact
switching (excited relay). Possible associations are:
Intrusion alarm
: the relay switches (for the alarm time) when the control panel receives an Intrusion alarm or a Tamper alarm.
Pre-alarm
:.the.relay.switches.when.the.input.1.is.activated..The.relay.stays.excited.until.the.Entry.time.is.elapsed..
Technological alarm
: the relay switches (for the alarm time) when the control panel receives a Technological alarm.
Rescue alarm
: the relay switches (for the alarm time) when the control panel receives a Rescue alarm.
Low battery/failure alarm
:.the.relay.switches.when.occurs.one.of.the.following.failures:.
Low.battery..
Failure.on.PSTn.telephone.line.or.no.GSM.network..
Burnt.fuse..
Bus.line.failure.
.
Failure.signallings.stay.active.until.failure.is.removed.
To.an.output.can.be.associated.only.one.of.the.above.mentioned.alarms.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•