water iNlet SySteM aFter deCeMber 2016
The water inlet system is composed of:
A) Input filter 3/4’’ with non-return valve;
B) One mechanical filter of 100 μm;
C) One pressure reducer set at 2.3 bar / 29 psi (not adjustable);
D) One water main connection pipe made of white LDPE (d=15mm 0,6 inches)
E) For Plus and One models one Cleaning system fed by the blue pipe made of LDPE (d = 12 mm - 0,47 inches)
F) EPDM 12 mm black pipe for steam (d = 12 mm - 0,47 inches)
G) Connection to the detergent tank black LDPE (d = 10 mm - 0,4 inches)
A
B-C
ø12 F
ø10 G
ø12 E
ø15 D
ø12 F
ø10 G
ø12 E
Figure 11
Water inlet after December 2016
detergent tank
Figure 12
CHEFTOP-BAKERTOP MIND.Maps™ PLUS and ONE ovens are equipped with a chemical tank installed
underneath the oven. CHEFTOP MIND.Maps™ Compact Ovens’ detergent tank is inside the oven structure.
Figure 12
CHEFTOP MIND.Maps™ Compact
CHEFTOP MIND.Maps™
The tank capacity changes according to the oven model:
■ 3 l + 0,8 l of reserve (0,66 gal + 28,15 floz)
■ 2 l + 0,8 l of reserve (0,44 gal + 28,15 floz) only for compact oven
75
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...