P19
JST XHP-2
1
CMB1
IN
Bottom temperature probe in oven with the
smoker predisposition)
2
GND
P20
AMP Modu II 4P
1
TAC1/2
+13V
Tachometer input TAC1 e TAC2
2
IN_ TAC1
3
IN_ TAC2
4
GND
P30
AMP Modu II
4P
1
TAC3/4
+13V
Tachometer input TAC3 e TAC4
2
IN_ TAC3
3
IN_ TAC4
4
GND
P21
1
21VAC
21V ac
21 V AC power supply from secondary
transformer
2
21V ac
3
12VAC
12V ac
12 V AC power supply from secondary
transformer
4
12V ac
P22
INARLOCK 5P 1F
(Black)
1
-
-
2
NGAS
Flame control board power supply - neutral
3
FGAS
Flame control board power supply - phase
4
TSA
Safety thermostat outward
5
TSR
Safety thermostat comeback
P32
JST XHP-2
1
PRES
IN
Pressure switch potential free input
2
GND
GND
P24
1 ÷ 6
-
-
E1
1
E1
Ground connection nut
E2
1
E1
Ground connection nut
Gas power board is equipped with 5 fuses. The function of these fuses are summarized in
table 23
.
table 23
PE2021A0 and PE2021B0 gas board fuses
N° oF
fUSE
NOMINAL
CUrrENT
NOMINAL
vOLTAgE
TypE
prOTECTEd CIrCUIT
F2
2A
250V
Fast (F)
Primary of the transformer (TR60 230V-12V 60VA)
F3
2A
250V
Fast (F)
Detergent pump (PD output on P4 socket)
F4
4A
250V
Time delay (T)
Secondary of the transformer (TR60 230V-12V 60VA)
F7
2A
250V
Fast (F)
Flame control board BRAHMA ECM113
F9
2A
250V
Fast (F)
Blowers premix gas
dATA
rANgE
Supply Voltage
100/240V-50/60Hz
Operating temperature range
-20°C +85°C
Ambient humidity
95% max at 40°C
Protection degree
IP 00
Spark Ignition time (TSP)
(TS - 1) s
< 1 s
1…60s
Recycling attempts
0..10
MOLEX Minifit
4P
MOLEX Microfit 6P
Fixing Screw
Fixing Screw
European flame control board
The BRAHMA ECM-113 flame control board is equipped with non-volatile lock-out, which means that a
restart from the safety shutdown condition can be accomplished only by a manual reset of the system.
The main technical data are summarized in
Table 24
.
Table 24
Brahma technical data
Response time in case of flame failure
Lockout time due to parasite flame (Tk)
111
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...