USB
It allows to
EXPORT PROGRAMS, IMPORT PROGRAMS, IMPORT PICTURES
UNOXDIR
UNOXDIR
Z-DATA
IMAGECONVERTER.EXE
IMAGE
UNOXDIR
1
2
4
5
3
To load the own pictures the USB stick needs to be properly c
�����
To import the pictures in the oven proceed as follows:
■ Enter the USER MENU;
■ Tap the PIN 4456;
■ Press USB function;
■ Press IMPORT PICTURES.
USE fUMES prOBE
Activate/Deactivate the use of the
fumes probe
ON/ OFF
ON
WASHINg BEfOrE
HOOd
Number of washing cycles run by the
oven before starting a hood washing
From 0 to 999
0
WASHINg dIAgNOSTIC
Activate/Deactivate the reading of the
pressure switch placed in the washing
system
ON/OFF
ON
WASHINg vALvES TypE
To choose the type of solenoid valves
used in the washing circuit
NORMAL
/ SELF –
CLEANING
NORMAL
WATErLESS MOdE
The steam setting bar in the manual
cooking program is deactivated
ON/OFF
OFF
1
download the UNOXDIR.zip folder
from the UNOX Infonet software
section
2
save the UNOXDIR.zip folder onto
your USB stick
3
unzip the UNOXDIR.zip folder that
you have just downloaded
4
open the UNOXDIR folder
5
there are two folders within this
folder (ZDATA and IMAGES) as well
as an .ex
�����
GECONVERTER.
EXE)Copy the images you want to
use into the IMAGE folder. Start the
IMAGECONVERTER.EXE program.
You can now use the images.
65
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...