Measurement of the inflow and outflow gas pressure
Necessary tool:
■ Differential pressure meter , suggested model: Testo 510
How to measure the static and dynamic
inflow pressure
, see
Figure 12
:
1. Unscrew the inflow gas pressure screw and connect the differential pressure meter;
2. Open the gas tap;
3. Read the static pressure value. The optimal value depends on the gas type according to UNOX specification;
4. Measure the inflow dynamic gas pressure while running the gas fumes test 1 (maximum power) and the
gas fumes test 2 (minimum power). The values should be closed to the static value.
How to measure the static and dynamic
outflow pressure
, see
Figure 12
:
1. Unscrew the outflow gas pressure screw and connect the differential pressure meter;
2. Open the gas tap and run the oven;
3. Read the pressure value. The value should be idea 0 ± 0.7 mbar (0 ± 0.28 inch wc);
4. Measure the static outflow gas pressure and check if the value is about 0 mbar (0 in H2O);
5. Measure the dynamic outflow gas pressure when running the gas fumes test 1 (maximum power and the
gas fumes test 2 (minimum power). The values should be about 0 ± 0.7 mbar (0± 0.28 In H20) as explained
in
section 4.4 Influence of the gas valve inflow pressure.
Gas pressure outflow screw
Gas pressure inflow screw
Figure 12
Measurement of the inflow and outflow pressure
108
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...