HOW TO IDENTIFY THE WRONG CABLE WITH
RESPECT THE RIGHT ONE
FRONT WRONG CABLE
BACK WRONG CABLE
FRONT CORRECT CABLE
OLD CABLE
NEW CABLE
BACK CORRECT CABLE
Figure 1
If during the software upgrading the oven shows you
the message “USB not found”, proceed as follows:
WRONG cable code is CE1052A0/ CE1054A0 on the
basis of the model you have.
CORRECT cable code is CE1052A1/CE1090A0 on the
basis of the model you have.
If during the software upgrading the oven shows
you the message FILE not found, proceed as follows:
■ Verify that inside the USB stick there is the UNOX-
DIR folder with inside at least the Software and
PARAM folders;
■ Verify the proper name of the file type and name
according to the electronic board that you are go-
ing to upgrade. Refer to the table below.
black
green
green
violet
ELECTrONIC BOArd
fW NAME
PE2038A0 PLUS electrical ovens power board
2038.bin
PE2037A0 ONE electrical ovens power board
2037.bin
PE2021A0 PLUS EU gas ovens power board
2021.bin
PE2022A0 PLUS USA gas ovens power board
2022.bin
PE2052A0 ethernet board
2052.bin
PE2053A0 Wi-Fi board
2053.bin
PE2054A0 EU 3G board
2054.bin
PE2064A0 3G Asia – Australia board
2064.bin
integrate WiFi board
1057_W.bin
PE1057A0 PLUS CAPACITIVE control board
1057.bin
PE1058A0 ONE RESISTIVE control board
1058.bin
PE1062A0 BIG CAPACITIVE control board
1062.bin
1
Format the USB stick using FAT32 system file;
2
If the USB stick is already FAT32 formatted, verify
the CONTROL/USB board connection cable
according to the following the Figure 1.
58
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...