rEf. dESCrIp-
TION
SUppLIEr
I
v
f
p
Q
S
pf
L
@
100Hz
r
@
100Hz
Z
@
100Hz
dCr X/r
θ
A
Contactor
VE1095A0 /
GE– CL01A400T
30
mA 230 V ~ 50 Hz 2 W
6 Var 6.5 Va 0.31 13 H 2 kΩ 9.4 kΩ 770 Ω 4.42 77.2°
B
Solenoid
valve
VE1135A0 /
RPE – SERIE R
30
mA 230 V ~ 50 Hz 4.7 W 4.5 Var 6.5 Va 0.72 9 H 4.7 kΩ 7.4 kΩ 4.3 kΩ 1.19 50°
C
Pump
VL1038A0 /
A.R.S. – MPP1
185
mA 140 V ~ 50 Hz 21 W 30 Var 36 Va 0.58 1.75 H 660 Ω 1.3 kΩ 580 Ω 1.66 59°
E
Fan
VN1162A0 /
SUNON – DP200A
130
mA 230 V ~ 50 Hz 21 W 19 Var 28 Va 0.75 3.4 H 1.1 kΩ 1.6 kΩ 626 Ω 1.11 48.1°
F
Motor
MT1012A0 /
SISME
1.62
240V
60 Hz 388W
-
-
-
-
30.5 kΩ
-
-
-
-
G
DRY.Maxi
solenoid
VE1135-VE1140-
VE1014
RPE SERIES R
-
230V
50 Hz
-
-
8VA
-
-
-
-
-
-
-
LEgENd
I
Load current consumption
v
Voltage applied to the load
f
Frequency
p
Load active power
Q
Load reactive power
S
Load apparent power
pf
Power Factor (PF=P/S)
l @ 100Hz
@ 100Hz measured inductance
r @ 100Hz
@ 100Hz measured resistance
Z @ 100Hz
@ 100Hz measured impedance
dCr
Measured resistance in DC
X/r
Q=|X/R| (X=reactance, R=resistence)
θ
angle between real axis and the impedance vector
Input
NAME
INpUT
dESCrIpTION
INpUT TypE
rANgE
SENSITIv-
ITy
prECISION HArdWArE
INpUT
CMB_1
Bottom temperature probe
Analogue PT100
0 – 300 °C
0.1°C
+/- 0.5 °C
√
CMB_2
Top temperature probe
Analogue PT100
0 – 300 °C
0.1°C
+/- 0.5 °C
√
BRD_TEMP
Board temperature probe
Analogue NTC
0 – 100 °C
5°C
+/- 5 °C
HEART_1
Mono-point core probe
Analogue PT100
0 – 300 °C
1°C
+/- 1 °C
√
TAC_1
Tachometer group 1 (speed)
Analogue
30 – 10K RPM
1 RPM
+/- 1 RPM
√
TAC_2
Tachometer group 2 (direction)
Analogue
30 – 10K RPM
1 RPM
+/- 1 RPM
√
VAC
Power supply alternate current
Analogue
0 – 260 VRMS
1 V
+/- V
VDC
V DC on modbus
Analogue
0 – 15 V
1 mV
+/- mV
IDC
DC current
Analogue
0 – 7 A
1 mA
+/- mA
AC_FREQ
Power supply frequency
Analogue
0 - 50 - 60 Hz
-
-
DOOR_1
Door switch 1
Digital
-
-
-
√
DOOR_2
Door switch 2 (trolley switch)
Digital
-
-
-
√
ALL_TS
Safety thermostat alarm
Analogue
-
-
-
ALL_TM
Motor thermal protection
Digital
-
-
-
12
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...