aM03 - SaFety tHerMoStat alarM
SLOWTOp
YES
NO
NO
NO
YES
Replace the cable
harness
End
NO
YES
YES
End
NO
YES
AM03 safety
thermostat alarm
Wait for the
Slowtop to
cooldown
Reset the thermostat
and analyse the
possible causes such as
S
lowtop installation,
external heating
sources
Replace the
safety
thermostat
Has the
safety thermostat
triggered? It
triggers at
320 C (608 F)
Turn off the power
supply. Disconnect
P6 socket of the
contactor and test
the electrical continuity
with the multimeter
set to ohm
Do you
have the
electrical
continuity?
Do you
have
electrical
continuity?
Measure the electrical
continuity of the
safety thermostat as
shown in the picture
with the multimeter s
et to ohm
Measure the electrical
continuity of the
cable from the P6
socket to the safety
thermostat plug.
Meaure the
conductivity
PIN to
PIN.
Do you
have the electrical
continuity in
the wiring?
Replace the
S
lowtop power
board
Restore the cable
harness and run
the slowtop
at 180 °C
Does the
alarm
persist?
205
Summary of Contents for MINDMaps BAKERTOP
Page 1: ...SERVICE MANUAL...
Page 138: ...OVEN Test to do Test 1 138...
Page 139: ...OVEN Pt100 Temperature Probe Resistance table 139...
Page 150: ...Test to do test 1 Measure the electrical conductivity of the micro switch OVEN 150...
Page 155: ...163 OVEN Pt100 Temperature Probe Resistance table 155...
Page 166: ...OVEN test 1 Measure the power supply to the washing solenoid valve 166...
Page 189: ...OVEN Pt100 Temperature Probe Resistance table 189...
Page 215: ...214...