Auto Download – replacing other modules
The DX System has a feature called Auto Download. It is designed to minimise
the programming requirements associated with Module servicing by down
loading the correct programming to a replacement DX Module.
Auto Download is achieved by DX remotes containing both their own
programming and also a backup copy of the programmed data for all other DX
Modules in the system. When a module is swapped, or a check sum error found
in a module, the DX Remote automatically down loads its backup copy to the
module. The Auto down load occurs immediately on power up after the module
has been replaced. This applies to all DX modules
except
a DX master remote.
I.e. When you replace a Genie Joystick it will need re-programmimg.
Warning!!
When a Genie Joystick is replaced it will perform an Auto Down load to all DX
modules. This may result in incorrect and dangerous programming for a
particular wheelchair system if the wheelchair program installed in the Genie
Joystick is not suitable for that wheelchair system.
Do not attempt to drive or test the DX system before the correct and suitable
wheelchair program has been installed in the Genie Joystick using the Wizard.
See page 63 “Downloading the correct DX wizard file”.
After replacing any DX Module, turn the DX System off, then on again, to initiate
the Auto down load of the DX Remote backup data. When a Auto Down load
has occurred the status LED of the replaced module will flash. Turn the system
off and them on again to clear this fault and complete the Auto Down load.