User Manual
Genie Joystick
Nov 07
©Unique Perspectives Ltd.
www.click2go.ie
Page 54
2. The Joystick Threshold parameter is fixed at 50%.
3. It takes a little longer to switch between operation modes.
NOTE:
If you want mouse movements using the Genie joystick to be non-
proportional set the Joystick_Threshold parameter to 50% (see next page).
Enable_My_Set
The Genie joystick offers the unique possibility of creating your own set of
operation modes to choose from and in what order you choose them. For
example one user may only want to switch between driving and computer
access whist another may wish to switch between driving, computer access,
seat function and drive profile selection. How to create this set is described later
in this chapter.
After creating your set of operation modes you must enable it by setting this
parameter to ‘Y’.
The default set of operation modes and the order in which they are presented is:
1. Computer Access
2. External Access
3. Seat control
4. Lights,
5. Select drive profile,
6. Power down.
Joystick_Threshold
In non-driving modes the joystick can be thought of as a 4 way switch.
Deflecting the joystick forward is one switch, deflecting the joystick left is
another and so on. The distance away from center that the joystick has to be
deflected before the movement is detected as a switch is called the joystick
threshold.
The joystick threshold also controls the mouse sensitivity. When set to fine a
very small deflection of the joystick will start the mouse moving. When set to
coarse a very large deflection of the joystick is required.
Value
Switch Detect %
Mouse sensitivity
1
12.5%
Fine
2
25% (default)
Standard
3
50%
Coarse (almost non-proportional)
Set this value to 3 if the user is prone to involuntary movements. Set this value
to 1 if the user can make small deflections on the joystick.