Settings by work [Work 0 to 15, All]
*2: [NOV RAM : N] [SRAM : S]
Item
Set value
Input range (display range)
Initial value
Memory
*
2
Settings by
work
Work No.
0 to 15
0
Copy No.
0 to 15
0
Measurement
Start
Condition
Setting
Start Condition
0 : Only External Input
1 : External Input + Load
2 : External Input + Displacement
(2 can be set only when the X-axis
of the waveform represents
displacement.)
External
Input + Load
S
Start Level
External Input + Load
: -9999 to +9999
External Input + Displacement
: -9999 to +32000
1.00Nm
S
Stop Condition
0 : Only Forced-Stop
1 : Load
2 : Time
3 : Displacement
4 : Displacement Stop
(3 and 4 can be set only when the
X-axis of the waveform represents
displacement.)
Only
Forced-Stop
S
Stop Level
Load: -9999 to +9999
Time: 0.1 to 10.0 [second]
Displacement: -9999 to +32000
Displacement Stop: 0.1 to 10.0
[second]
1.00
S
Display
Range
Setting
Y Start Point
-10000 to 10000
0.00Nm
S
Y End Point
Y-axis Start Point +
0 : 25
1 : 50
2 : 100
3 : 200
4 : 300
5 : 400
6 : 500
7 : 1000
8 : 2000
9 : 3000
10 : 4000
11 : 5000
12 : 10000
13 : 20000
20.00Nm
S