44
TROUBLESHOOTING:
in the event of a malfunction, carry out the following
checks.
1. The LED does not light up: check that the stove is electri-
cally powered, that the main switch is in position 1 and that
the fuse is not blown.
2. The LED does not light up: check that the sanitiser power
button is pressed.
3. Failure to operate: check the condition of the condenser
by cleaning its housing of any dust or particles deposited
at the base.
4. Lack of maintenance: clean the condenser or check its
condition, if the quartz or internal mesh is white it must be
replaced. If oxide is present on the outer mesh, it means
that the condenser has not been properly maintained, and
if a lot of oxide is deposited, this will impair the functioning
of the device.
5. The device is equipped with useful slots and openings for
ventilation, never obstruct or cover the slots and ensure
that they are always free of dust or obstructive elements
SPARE PARTS:
The ionising condenser should be replaced every 11 to 18
months or when a whitish layer is noticed on the wire grille
inside the glass. Request the component from an authorised
technician.
KIT REQUEST:
Contact an authorised dealer to request the Air Sanitiser Kit
and its installation.