![Unical NUA Installation And Maintenance Instructions Manual Download Page 73](http://html1.mh-extra.com/html/unical/nua/nua_installation-and-maintenance-instructions-manual_3983475073.webp)
19
Z
G
Z
Y1
X2
Z
X1
Z
Z
(S)
(S)
(B)
Y1
Uscita fumi
posteriore
Uscita fumi
laterale
Uscita fumi
superiore
( )
B
Zona di sicurezza aria calda
1200 mm
600
mm
X2
( )
B
X2
Y1
(S)
Y1
(S)
Z
G
X1
X1
Installation instructions
3.4 - MINIMUM SAFETY DISTANCES AND
INTERVENTION
Installation adjacent to combustible or heat-sensi-
tive materials is permissible provided that suitable
safety distances are interposed, see drawing
MINIMUM SAFETY DISTANCES
Pos.
Description
mm
Z
TOP
200
Y1 (S) RIGHT / LEFT SIDE
200
X2 (B) REAR
200
X1
FRONT
600
G
FLOOR
0
In the interests of safety, it is advisable to
maintain a safe distance between the hot
sides of the stove and any flammable cladding
materials (e.g. sloping walls, wallpaper, etc.),
or to use commercially available insulation
materials.
See the technical data tables for the required
safety distances for each model.
In the case of non-flammable materials, a side and rear clear
-
ance of at least 200 mm must be maintained.
Whereas for product maintenance, a side and rear clearance of
at least 500mm must be maintained.
For products with rear spacers, installation flush with the wall is
only permitted at the rear.
The product must be installed in a location that allows safe and
easy operation and maintenance.
This place must also be equipped with an electrical system with
earthing as required by current standards.
It may be necessary to distance the product from adjacent
walls to perform extraordinary maintenance.
This operation must be carried out by a qualified technician
to disconnect the combustion product exhaust pipes and the
subsequent connection,
such operations are not under war-
ranty.
Rear smoke
outlet
Side smoke
outlet
Top smoke outlet
Hot air safety zone
Summary of Contents for NUA
Page 11: ...11 Informazioni generali PAGINA LASCIATA VOLUTAMENTE BIANCA ...
Page 65: ...11 General information PAGE INTENTIONALLY LEFT BLANK ...
Page 110: ......
Page 111: ......