M08 STOVE STATUS
This function is reserved for the AUTHORISED TECHNI-
CIAN.
The menu contains the most important values provided by
the actual input and output signals of the circuit board dis-
played in real time.
M08
ST
OVE ST
ATUS
Temp. FLUE
GAS
C°.....
Flue gas probe temper-
ature
Temp. ROOM
C°..... /
on-off
Room probe temp. en-
abled/on-off thermostat
(opt.)
Temp. DUCT.
1
C°..... /
on-off
Ducted probe
temp.1(right)/duct. ther-
mostat on-off 1 (opt.) IF
AVAILABLE
Temp. DUCT.
2
C°..... /
on-off
Ducted probe
temp.2(left)/duct. ther-
mostat on-off 1 (opt.) IF
AVAILABLE
FLUE GAS
RPM
Rpm... Flue gas suction speed
Vel. ROOM
Volt...
Front-top room fan speed
Vel. DUCT. 1
Volt...
Ducted fan speed 1
(right). IF AVAILABLE
Vel. DUCT. 2
Volt...
Ducted fan speed 2 (left).
IF AVAILABLE
TIMEOUT
Min-
utes...
Time for the next auto-
matic brazier cleaning
Del. AL.
Sec.
Delay time to display
alarm
SERVICE
Hours
Time remaining for SER-
VICE
M09 TECHNICAL SETTINGS
It is a menu reserved for the AUTHORISED TECHNICIAN.
ATTENTION:
Modification of technical parameters on the 09
menu must be carried out by authorised and
competent personnel; any changes made in a
haphazard manner may result in serious damage
that for which the manufacturer will not be held
liable.
M10 PELLET TYPE
This function serves to regulate the supply of pellets to
the brazier at all stages of operation of the product.
The modified value affects the speed of the loading mo
-
tor, from +1....to....+9 the speed increases proportionally
by increasing the amount of pellets falling, vice versa
from -1....to....-9 the speed decreases by reducing the
amount of pellets...
The default value is '0'.
ATTENTION:
an excessive decrease in the speed of the load-
ing motor could cause the flame to extinguish
due to a lack of pellet supply in the brazier and
consequently "ALARM 06 NO PELLETS".
M11 CHIMNEY TYPE
This function is used to regulate the combustion air in
case the flame is too oxygenated or not enough.
The modified value affects the speed of the smoke
extractor, from +1....to....+9 the speed increases pro
-
portionally by increasing oxygenation, conversely from
-1....to....-9 the speed decreases by reducing oxygena
-
tion.
The default value is '0'.
ATTENTION:
an excessive decrease in the speed of the
extractor could generate an excessive formation
of unburnt fuel as well as a decrease in negative
pressure inside the combustion chamber with the
appearance of random 'NO VACUUM ALARMS
08'.
M12 RESET U-IN
The menu is used to reset the stove/wi-fi configuration.
After selecting ON, it is necessary to confirm by press
-
ing OK (7).