UTG9000T Series Function Abitrary Waveform Generator
39
Comprehensive example
In AM modulation mode, set an internal 200Hz sine wave as a modulating signal, another carrier wave
signal with freqeuency 10kHz, amplitude 200mVpp, duty ratio 45%, and set the modulation depth to 80%,
the settings steps as following,
1
)
Turn on AM modulation mode: tap CH1
→
Modulate
→
AM accordingly.
2
)
Set the parameter of modulating signal
Base on the step 1) to tap ModFreq tab to pop-out visual numeric keyboard to enter 200Hz.
3
)
Set the parameter of the carrier wave signal
Tap Base to select Square as the carrier waveform (the default option is sine wave).
Tap Freq tab to pop-out visual numeric keyboard to enter 10kHz.
Tap Ampl tab to pop-out visual numeric keyboard to enter 200mVpp.
Tap Duty tab to pop-out visual numeric keyboard to enter 45%.
See the Figure as following,