2
)
Set the parameter of the carrier wave signal
Tap Base to select sine as the carrier wave (the default option is sine), so this step has no
change.
Tap Freq to pop-out visual numeric keyboard to enter 10kHz.
Tap Ampl to pop-out visual numeric keyboard to enter 2Vp.
Tap REdge to pop-out visual numeric keyboard to enter 100ns.
Tap FEdge to pop-out visual numeric keyboard to enter 100ns.
3
)
Set the modulating parameter
After the parameter setting of the carrier wave, tap Type to return to modulation interface to
set the parameter.
Tap ModFreq to pop-out visual numeric keyboard to enter 1kHz.
Tap DutyDev to pop-out visual numeric keyboard to enter 40%.