ULTRA SECURE
www.ultrasecuredirect.com
15
To receive information concerning the opening times of the relays, you can send
the following status request command:
1234#RT
Variable data
Meaning
1234
Default password, to be adapted if the password is changed.
This command allows you to receive the duration set for each relay.
Open and close relays
Users and secondary users can open the relays at any time using the following
SMS command:
1234#Rn#O
Variable data
Meanings
1234
Default password, to be adapted if the password is changed.
n
Relay number between 1 and 2.
Attention, it is the letter O in capitals and not the number 0.
The opening of the relays is also possible during a call from the panel or
during a call to the panel (
see page 13
). Finally, this is also accessible if
you have wired switches directly to the connection terminal block via the
SW and GND terminals (
see next section
).
To close the relays, you need to send the following SMS command:
1234#Rn#C
Variable data
Meanings
1234
Default password, to be adapted if the password is changed.
n
Relay number between 1 and 2.
Use of switches to open relays
The UltraCOM 4G terminal block has SW and GND terminals for each relay output
(
see page 6
), allowing you to wire a switch.
To do this, simply connect your switch (
not supplied
) to the SW-1 and associated
GND (
or SW-2 and associated GND
) terminals in order to activate relay 1 (
or relay
2
) when this switch is triggered. The relays will then be opened according to the
defined duration.