PRE-INSTALLATION:
Safe and satisfactory operation of a Model PAR-3-HE gas fryer depends on its proper installation. Installation
must conform to local codes or, in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1 (latest edition). In
Canada, gas installation shall be in accordance with the current CAN/CGA B 149.1 and .2 installation codes and/or local codes.
A. GENERAL:
Each Model PAR-3-HE fryer should be installed as follows:
1. Placed beneath a properly designed exhaust hood
2. Installed by a licensed plumber.
3. Connected to the type gas for which the unit was fabricated as shown on the rating plate.
4. Connected to the proper size pressure regulator installed in the gas supply line and adjusted to the proper manifold pressure.
5. Connected to the main gas supply line with the proper size supply line.
6. Restrained by use of a restraining device to avoid splashing of hot liquid and to assure tension cannot be placed on the flexible
gas line or fittings.
CLEARANCES
: The appliance must be kept free and clear of all combustibles. The minimum clearance
from combustible and non-combustible construction is 6” (152 mm) from the sides, and 6” (152 mm) from rear. The fryer
may be installed on combustible floors.
NOTE
: Adequate clearances must be provided for servicing and proper operation.
B. STANDARDS:
Installation must be planned in accordance with all applicable state and local codes, taking into account the following
standards:
1. The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing
of that system at pressures in excess of 1⁄2 psig (3.45kPA). In Canada, gas installation shall be in accordance with the current
CAN/CGA B 149.1 and .2 installation codes and/or local codes.
2. The fryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pres-
sure testing of the gas supply piping system at pressures equal to or less than 1⁄2 psig (3.45kPA).
3. When installed the fryer must be electrically grounded in accordance with local codes, or in the absence of local codes, in
accordance with the current National Electrical code ANSI/NFPA 70 (latest edition). In Canada electrical installation must be
in accordance with the current CSA C22.1 Canadian Electrical Code and/or local codes.
4. Other applicable nationally recognized installation standards such as:
a. National Fuel Gas Code ANSI Z223.1 (latest edition)
American Gas Association
1515 Wilson Blvd.
Arlington, VA22209
b. NFPA Standards #54, #94 and #221 (latest edition)
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110
c. ANSI Z21.69/CAN/CGA-6.16 AND Z21.41/CAN1 6.9
5. Exhaust vent hood, when installed must conform to the current NFPA 54-1 and Canadian CAN/CGA-1.11 (latest edition)
NOTE:
Local building codes will usually not permit a fryer with its open tank of hot oil to be installed immediately next to an
open flame of any type, whether a broiler or an open burner or range. Check local codes before beginning installa
tion.
C. AIR SUPPLY AND VENTILATION:
The area around the appliance must be kept clear of any combustible or flammable products
and avoid any obstruction to the flow of ventilation air as well as for ease of maintenance and service.
NOTHING
is to be stored
in the interior of the fryer’s cabinet except the filter tub assembly.
1. A means must be provided for any commercial, heavy duty-cooking appliance to exhaust combustion wastes outside of the
building. It is essential that a fryer be set under a powered exhaust vent hood or that an exhaust fan be provided in the wall
above the unit, as exhaust temperatures are in the vicinity of 400°F (204ºC).
NOTE:
Strong exhaust fans in a hood or in the overall air conditioning system can produce slight air drafts in the room, which
can interfere with burner performance and be hard to diagnose. Air movement should be checked during installation and
if burner problems persist, make-up air openings or baffles may have to be provided in the room.
2. Exhaust temperature, in addition to the open tank of hot oil, make the storage of anything on shelving over or behind the
fryer unsafe.
3. Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any
hood.
4. Provisions must be made for an adequate supply of fresh air and adequate clearance must be maintained for air openings into
the combustion chamber.
Page 8 of 61
Summary of Contents for PAR-3-HE
Page 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Page 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Page 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Page 18: ...30A135 INITIAL START UP Page 14 of 61...
Page 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Page 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Page 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Page 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Page 31: ...30A135 CLEANING Page 27 of 62...
Page 36: ...30A135 FRYER OPERATION Page 32 of 61...
Page 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Page 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Page 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Page 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Page 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Page 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Page 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Page 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Page 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...